FinMark UTP 2P 24AWG outdoor twisted pair cable 500 m
FinMark UTP 2P 24AWG outdoor twisted pair cable 500 m
- Number of pairs 2
- Cable type UTP
- Category 5/5e
- Application Outside
- Shell Material Polyethylene (PE)
- Length as packaged 500 m
Help required?
Leave us a note and we will contact you as soon as possible!
Description
Description/application:
2-pairs UTP cable Cat 5 FinMark is used in local data networks: PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s.
Compliance with the standards:
- ISO/IEC 11801
- ANSI/TIA/EIA-568В.2
- EN50173
- YD/T1019-2001
Cable is used for permanent installation inside buildings, plants, structures and equipment. Fully copper conductors 24AWG ensure reliable operation of the lines at maximum distances.
Design:
Cable sheath is made of black UV stabilized PVC. The cable consists of 2 pairs of wires twisted together.
Wires color identification:
pair 1: white-blue/blue
pair 2: white-orange/orange
Packing:
The length of the cable on the reel is 500 meters.
Electrical characteristics:
| Impedance, Ohm | (100±15) |
| DC resistance, Ohm/km | 94 |
| Propagation speed | 0,68×s |
Technical Performance:
| Frequency MHz | Attenuation dB/100m | NEXT, dB | ELFEXT, dB | RL, dB |
| 1 | 2,0 | 65,3 | 63,8 | 20,0 |
| 4 | 4,1 | 56,3 | 51,7 | 23,0 |
| 8 | 5,8 | 51,8 | 45,7 | 24,5 |
| 10 | 6,5 | 50,3 | 43,8 | 25,0 |
| 16 | 8,2 | 47,3 | 39,7 | 25,0 |
| 20 | 9,3 | 45,8 | 37,7 | 25,0 |
| 25 | 10,4 | 44,3 | 35,8 | 24,3 |
| 31,25 | 11,7 | 42,9 | 33,9 | 23,6 |
| 62,5 | 17,0 | 38,4 | 27,8 | 21,5 |
| 100 | 22,0 | 35,3 | 23,8 | 20,1 |
Mechanical properties:
| Cable O.D. , mm | 4,5 | |
| Conductor material | Copper wire, diameter 0,50 mm (24 AWG) | |
| Conductor isolation —PE, isolated conductor diameter, mm | 0,9 | |
| Temperature range | installation, °C | -10 … +60 |
| operating, °C | -30 … +60 | |
| Min bending radius | During installation (dynamic) | ≥ 8 x cable diameters |
| After installation (constant) | ≥ 4 x cable diameters | |
| Tensile stress, N | ≤ 80 | |