FinMark UTxxx-SM-02 optical cable
FinMark UTxxx-SM-02 optical cable
- Cable type UT
- Design Armored
- Application Soil, in cable-conduit lines, tunnel, entering into the building
Help required?
Leave us a note and we will contact you as soon as possible!
Description
Use:
For laying in all types of soil (without cryosolic deformations), in cable-conduit lines, in pipes, on bridges, in tunnels, collectors at the entry into a building, including places infested with rodents.
Design:
Cable with a central optical module, which can contain up to 24 optical fibers. At the perimeter of central module an armor from round steel braidings is placed. Cavities between braiding armour are filled with hydrofobic water-blocking compound. Second armour layer is made from steel goffer band, and apart from providing mechanical protection, serves as a hydrobarrier preventing moisture diffusion through polymeric coatings towards optical fiber. External coating is made from UV-stabilized polyethylene of high density.
Specifications:
|
Amount of fibers, pcs. |
2 – 6 |
8 – 12 |
14 – 24 |
|
|
Diameter of optical module, mm |
2.5 |
3.0 |
3.6 |
|
|
Diameter of steel braiding, mm |
0.8 |
|||
|
Outer coating thickness, mm * |
2 |
|||
|
Diameter of cable, mm * |
9.9 |
10.4 |
11.0 |
|
|
Cable mass, kg/km ** |
136 |
153 |
171 |
|
|
Min. bending radius, constant/dynamic |
10 / 20 cable diameters |
|||
|
Max. tensile force, N |
3000 / 1200 (short-term/long-term) |
|||
|
Max. compressive load, N/100mm |
2000 / 600 (short-term/long-term) |
|||
|
Allowable temperatures |
operation |
-40°C – +60°C |
||
|
storage |
-50°C – +70°C |
|||
|
install. |
-20°C – +50°C |
|||
(*) – allowable deviation +/- 0.2 mm
(**) – averaged
An optical fiber Fujikura FutureGuide is placed in the cable – LWP (complies with ITU-T G.652.D) its specifications you can find here. On a client’s demand cable can be manufactured with fibers byITU-T G.655
Description of colour marking of optical fibers you can find here
Symbolic notation of FinMark optical cables you can find here.