FinMark 540 series trunk coaxial cable

Choose the options that you are interested in.

Description

Designation Description Cable weight, kg/km Shipping weight, kg/km
QR 540 JCA Copper-clad aluminium centre conductor, solid tube outer conductor, polyethylene jacket. 137 190
QR 540 JCAM109 Self-supporting aerial cable with figure-8 messenger wire. 196 257

Cable element dimensions:

 
Element mm
Nominal centre conductor diameter 3.15
Nominal diameter over dielectric 13.03
Nominal diameter over outer conductor 13.72
Nominal outer conductor thickness 0.343
Nominal diameter over jacket 15.49
Nominal jacket wall thickness 0.89
Steel messenger wire diameter (for messenger version) 2.77

Mechanical characteristics:

  • Minimum bending radius: 10.2 cm;
  • Maximum tensile force: 100 kgf;
  • Minimum messenger wire breaking force: 816 kgf.

Electrical characteristics:

  • Capacitance, nF/km: 50 ± 3.0;
  • Characteristic impedance, Ohm: 75 ± 2;
  • Velocity of propagation, %: 88.

Maximum DC resistance (at 20°C):

Copper-clad
Inner conductor 3.34 Ohm/km
Outer conductor 1.94 Ohm/km
Loop resistance 5.28 Ohm/km
Solid copper
Inner conductor 2.20 Ohm/km
Outer conductor 1.94 Ohm/km
Loop resistance 4.14 Ohm/km

Attenuation (at 20°C):

Frequency, MHz Nominal, dB/100 m Maximum, dB/100 m
5 0.43 0.46
30 1.12 1.12
45 1.35 1.35
50 1.41 1.44
55 1.48 1.54
83 1.80 1.90
108 2.07 2.17
150 2.43 2.59
181 2.76 2.89
193 2.85 2.95
211 2.99 3.12
220 3.05 3.22
250 3.25 3.38
270 3.38 3.51
300 3.54 3.71
325 3.71 3.87
350 3.84 4.03
375 4.00 4.17
400 4.13 4.33
425 4.27 4.49
450 4.44 4.59
500 4.63 4.89
550 4.95 5.12
600 5.23 5.38
750 5.92 6.07
865 6.23 6.56
1000 6.91 7.12